S300 Professional

Share:


S300 Professional



 At a glance

  • Compact design
  • 2 m or 3 m protective field range
  • 270° scanning angle
  • 8 switchable field sets
  • Configuration memory integrated in the system plug
  • EFI interface for safe SICK device communication
  • Incremental encoder inputs for speed-dependent field switching
  • Measured data output via RS-422

Your Benefits

  • Simple integration due to compact design
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Unbeatable cost-effectiveness – 270° scanning angle allows complete application protection with only two scanners
  • Variety of field sets guarantees safety and productivity when protecting vehicles or moving machine parts
  • Quick recommissioning via configuration memory
  • Easy modular expansions, simple cabling and additional functions using SICK safety controllers with EFI
  • The correct protective field at any speed avoids unnecessary stops
  • Personnel protection and navigation support in one device

High-performance – the right protection for any speed

The S300 Professional meets exacting requirements and meets the demands of mobile applications thanks to its extensive functionality. Up to eight protective fields can be configured. The new triple field mode allows three fields – one protective field and two warning fields – to be activated at the same time. The use of the integrated EFI interface extends interoperability with other safety laser scanners and safety controllers from SICK. This means automatic guided vehicles (AGVs) can be given all around protection and matching safety fields, regardless of speed. The configuration memory integrated into the system plug also enables simple commissioning and quick device replacement.

Technical data overview

Protective field range 2 m / 3 m
Warning field range 8 m
Scanning angle 270°
Number of fields 24
Number of monitoring cases 32 1)
Resolution 30 mm, 40 mm, 50 mm, 70 mm, configurable
30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable
OSSD pairs 1
Response time 80 ms 2)
Safe device communication EFI
1) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise eight.
2) Depending on basic response time and multiple sampling.

 Inquiry - S300 Professional