UE10-3OS

Share:


UE10-3OS



At a glance

  • Ideal for applications with opto-electronic protective devices and safety controllers with OSSD outputs
  • Output expansion for a safe processing of OSSD output signals
  • 3 safety outputs, 1 application diagnostic output
  • Feedback path for external device monitoring (EDM)
  • Coded plugs for all slots

Your Benefits

  • Offers all needed contact paths in a compact form
  • Fast diagnostics via status information reduces downtime
  • Fast, tool-free exchange via coded, plug-in screw-type terminals
  • Combines the advantages of classic relays and easy circuitry

Technical data overview

Applications Output expansion module for OSSDs
Compatible sensor types Opto-electronic protective devices
Safety integrity level SIL3 (IEC 61508) 1)
SILCL3 (EN 62061) 1)
Category Category 4 (EN ISO 13849) 1)
Performance level PL e (EN ISO 13849) 1)
Reset Automatic
External device monitoring (EDM) Via path
Number of enable current contacts 3
Number of application diagnostic outputs 1
1) If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit.